Bright Anodized parts Don't Pass the Cass Test
Question: I have a roll-formed part made of 5052 alloy aluminum sheet.
Question:
I have a roll-formed part made of 5052 alloy aluminum sheet. This part is required to have a bright anodized finish, but the part being produced now will not pass the CASS requirements. I’m wondering if there is another anodized finish that will pass the testing requirements and still have the visual appearance that is required. I’m thinking in particular about hard anodize. Is there a cost difference between what we are doing now and hard
anodizing? B.C.
Answer:
There could be a couple of issues with the part not passing the CASS test. For the benefit of the readers let me first review the requirements of the CASS Test. CASS stands for “Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing.” It is performed in accordance with the procedures set forth in ASTM B 368. It essentially follows the procedures of ASTM B 117 Salt Spray Test, i.e., carried out in the same type of salt spray chamber, but to the standard 5% (wgt) salt solution (NaCl adjusted to pH 6.0 to 7.0) is added 0.25 grams of copper chloride. This solution is then acidified with acetic acid to a pH of 3.1 to 3.3. The length of testing is determined by the customer/end user. It is generally anywhere from six to 720 hours. The performance criteria is also up to the customer. For example, the customer should call out the number of corrosion sites allowed, their size, etc., in accordance with the end use requirements.
Two processing issues immediately come to mind. First, the sealing process simply may not be performing properly. Second, there may not be enough anodic coating thickness to give the protection required from exposure of the salt spray. Putting a hardcoat anodized finish on the part may not be the answer since it sounds like you are producing a specular (highly reflective) part. Hardcoat anodizing can be used on some bright parts to obtain a pleasing finish, but usually hardcoat anodizing is associated with industrial or high performance parts where appearance is not as critical as performance. Hardcoat anodizing done properly certainly will give a hard, dense anodic coating. My suggestion would be to try it and see if it makes a difference in the test performance and is still acceptable visually. You did not say what coating thickness is required. The coating thickness can affect both the performance and the brightness of the part.
Another possible solution to the problem is simply to do a better job of sealing. That’s relative because I have no way of judging the quality of seal you are getting now. We know that whatever it is, it is not good enough to pass the performance criteria of the test as determined by the customer.
You don’t mention what sealing bath/process you are using, so it’s difficult to give you specific trouble shooting hints. For a mid-temperature nickel acetate bath, for example, the bath temperature should be around 1,800°F ±5. Bath concentration should be up to the recommended strength in accordance with the manufacturer’s instructions. This is generally between 0.5 g/liter and 3.0 g/liter. The bath should be largely free of contaminants. Have you tried dumping the existing bath and making up a new one? Be sure to use only deionized (DI) water with a minimum electrical resistance of 200,000 ohms. This is the same as five micro-Siemens specific conductivity. If the bath is more than 60–90 days old, it may be too contaminated to permit a good quality seal. Of course, the degree of contamination depends on how well the bath is maintained. Ideally, there should be a good quality deionized rinse just prior to the seal and the sealing bath should be continuously filtered using a 5µ filter media, preferably pleated or wound polypropylene filter cartridges. I would be interested to find out more specifics about your seal. What are you using, what concentration and temperature, status of DI rinses, filter system, size of your tanks, etc. Any of that kind of information you could give me would be helpful. Please let me hear from you about this and we can start zeroing in on the cause of the problem.
Yes, there would most likely be a cost difference if you were to change the anodizing spec to hardcoat. I can’t say how much because I have no details about your current finish. Check with your anodizer. Hardcoat finishes rank right at the top as far as cost is concerned.
Related Content
10 Anodizing Best Practices
Following this list of guidelines can help to increase the performance, cost effectiveness and quality for your anodizing operation.
Read MoreAn Interview With Bryan Leiker, Metal Finishers Association of California
Bryan Leiker, executive director for the Metal Finishers Association of California (MFACA), offers an update on actions to counter a proposed ban on hexavalent chromium plating and anodizing operations in the state.
Read MoreFinisher’s ‘Top Shop’ Status Attracts Business
This competitive California finisher made it a goal to become a PF Top Shop. After earning the recognition, the company experienced an immediate increase in business and a challenge to obtain certifications.
Read MoreA Smooth Transition from One Anodizing Process to Another
Knowing when to switch from chromic acid anodizing to thin film sulfuric acid anodizing is important. Learn about why the change should be considered and the challenges in doing so.
Read MoreRead Next
Masking Solutions for Medical Applications
According to Custom Fabricating and Supplies, a cleanroom is ideal for converting, die cutting, laminating, slitting, packaging and assembly of medical-grade products.
Read MoreA ‘Clean’ Agenda Offers Unique Presentations in Chicago
The 2024 Parts Cleaning Conference, co-located with the International Manufacturing Technology Show, includes presentations by several speakers who are new to the conference and topics that have not been covered in past editions of this event.
Read MoreEpisode 45: An Interview with Chandler Mancuso, MacDermid Envio Solutions
Chandler Mancuso, technical director with MacDermid Envio discusses updating your wastewater treatment system and implementing materials recycling solutions to increase efficiencies, control costs and reduce environmental impact.
Read More